Electronic leak detector probe held against brazed copper pipe joints

F-gas leak checks and records in County Fermanagh

Stay compliant in County Fermanagh: F-gas leak checks arranged, recorded and followed up.

  • Price confirmed before booking
  • Every system listed and checked
  • Records you can show an inspector

How much do F-gas leak checks cost in County Fermanagh?

In County Fermanagh, guide prices are about £135–£225 per visit, first system, plus VAT. A typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT. We confirm the price once we know how many systems you have.

An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.

Where we work around County Fermanagh

We cover all of County Fermanagh, including Enniskillen. Each town below has its own page with local guide prices.

Postcode districts we cover include BT74, BT92, BT93 and BT94. We give you the records in a form an inspector, insurer or landlord can read, and remind you when the next check is due.

What is included

  • Leak check by an F-gas certified engineer
  • Direct and indirect checks to the required method
  • Labels and records updated
  • Leak repair quote if a leak is found
  • Follow-up check within one month of any repair

Prices in County Fermanagh

Guide prices for County Fermanagh, set for Northern Ireland. Your fixed price comes in writing.

F-gas leak checks guide prices, County Fermanagh
ItemGuide price (ex VAT)Inc VATBasis
Leak check, first system (includes attendance)£135–£225£162–£270per visit
Each additional system, same visit£60–£115£72–£138per system
F-gas asset register set-upUp to £365Up to £438per site
Automatic leak detection system£730–£2,695£876–£3,234per system

Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.

How a visit in County Fermanagh works

  1. Asset check

    We record each system's refrigerant type and charge and calculate its CO2e.

  2. Set the frequency

    Each system gets the legal interval for its CO2e and any automatic leak detection.

  3. Check

    The engineer checks joints, valves, components and operating data for signs of leakage.

  4. Record

    Results are recorded and kept on your F-gas log for at least five years.

What to think about in County Fermanagh

Northern Ireland

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573 rather than the GB rules. For HFC systems the leak-check thresholds and intervals are the same; it also requires checks on equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants.

Shared buildings

In multi-let buildings, roof space, risers and plant areas are often controlled by a managing agent. We work to their permits and method-statement requirements.

Repairs

If a leak is found it must be repaired without undue delay and re-checked within one month.

Neighbours and noise

Outdoor units near flats — common above shops — need careful siting so noise at neighbours' windows stays low. We choose positions and quieter units with that in mind.

Who we work with in County Fermanagh

In Northern Ireland, systems holding 5 tonnes CO2 equivalent of refrigerant or more fall under EU F-gas rules that apply in Northern Ireland, with regular leak checks and records; buildings with more than 12 kW of air conditioning in total also need a periodic energy inspection.

FAQs for County Fermanagh

How much do F-gas leak checks cost in County Fermanagh?

In County Fermanagh, guide prices are around £135–£225 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT.

Do you also cover County Tyrone, County Armagh and County Londonderry?

Yes. Alongside County Fermanagh, we also cover County Tyrone, County Armagh and County Londonderry. Each has its own page with local guide prices.

Which systems need F-gas leak checks in Northern Ireland?

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573. For HFC systems the thresholds and intervals match the GB rules — checks from 5 tonnes CO2 equivalent, at least every 12, 6 or 3 months depending on size — and equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants, also needs checks.

What is CO2 equivalent?

The refrigerant charge in kilograms multiplied by its global warming potential (GWP), divided by 1,000. It puts every refrigerant on the same scale.

How often are leak checks needed?

At least every 12 months from 5 tonnes CO2e, every 6 months from 50 tonnes, and every 3 months from 500 tonnes. Where automatic leak detection is fitted, each interval doubles to 24, 12 and 6 months.

Need F-gas leak checks in County Fermanagh?

The visit price is agreed before we book. We reply with a guide price or available dates.