F-gas leak checks and records in Antrim
F-gas leak checks in Antrim, with the paperwork handled for you.
- Price confirmed before booking
- Every system listed and checked
- Records you can show an inspector
How much do F-gas leak checks cost in Antrim?
In Antrim, guide prices are about £135–£225 per visit, first system, plus VAT. A typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT. We confirm the price once we know how many systems you have.
An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.
Where we work around Antrim
In a town like Antrim, a single wall unit for a shop or a cassette for a surgery makes a real difference in summer. Belfast is about 23 km away.
We cover every Antrim postcode, including BT41. Neighbouring towns we cover include Ballymena, Newtownabbey and Belfast. Compliance visits in Antrim are booked around your opening hours and the paperwork is kept for you afterwards.
What the job covers
- Refrigerant type, charge and CO2e calculation for each system
- Leak check by an F-gas certified engineer
- Direct and indirect checks to the required method
- Labels and records updated
- Follow-up check within one month of any repair
Guide prices in Antrim
These guide prices are adjusted for Northern Ireland, where labour and access costs run about 8% below the UK guide.
| Item | Guide price (ex VAT) | Inc VAT | Basis |
|---|---|---|---|
| Leak check, first system (includes attendance) | £135–£225 | £162–£270 | per visit |
| Each additional system, same visit | £60–£115 | £72–£138 | per system |
| F-gas asset register set-up | Up to £365 | Up to £438 | per site |
| Automatic leak detection system | £730–£2,695 | £876–£3,234 | per system |
Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.
How a visit in Antrim works
Asset check
We record each system's refrigerant type and charge and calculate its CO2e.
Set the frequency
Each system gets the legal interval for its CO2e and any automatic leak detection.
Check
The engineer checks joints, valves, components and operating data for signs of leakage.
Record
Results are recorded and kept on your F-gas log for at least five years.
Things to check in Antrim
Northern Ireland
Northern Ireland follows the EU F-gas Regulation (EU) 2024/573 rather than the GB rules. For HFC systems the leak-check thresholds and intervals are the same; it also requires checks on equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants.
Access and parking
Town-centre jobs in Antrim often come down to access — loading restrictions, parking for the van and getting equipment onto a roof. We check this at survey and plan deliveries around it.
Certified engineers
Leak checks must be done by an engineer holding the right F-gas certification.
Roof and height work
Flat roofs, high walls and atriums need the right access equipment and edge protection. We plan towers, MEWPs or scaffold before the job, not on the day.
Types of premises we cover in Antrim
- Hotels and hospitality: quiet bedroom units, public-area cooling and heat recovery for hotels.
Two rules matter for most businesses in Northern Ireland: EU F-gas rules that apply in Northern Ireland (leak checks from 5 tonnes CO2e) and the periodic energy inspection for more than 12 kW of air conditioning.
Your questions answered
How much do F-gas leak checks cost in Antrim?
In Antrim, guide prices are around £135–£225 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT.
Do you also cover Ballymena, Newtownabbey and Belfast?
Yes. Alongside Antrim, we also cover Ballymena, Newtownabbey and Belfast. Each has its own page with local guide prices.
Which postcodes do you cover in Antrim?
All of them, including BT41. Give us your postcode when you enquire and we will confirm the visit details.
Which systems need F-gas leak checks in Northern Ireland?
Northern Ireland follows the EU F-gas Regulation (EU) 2024/573. For HFC systems the thresholds and intervals match the GB rules — checks from 5 tonnes CO2 equivalent, at least every 12, 6 or 3 months depending on size — and equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants, also needs checks.
How long must records be kept?
For at least five years, covering refrigerant type and quantity, additions and recoveries, leak-check dates and results, and who carried out the work.
Who is responsible for F-gas compliance?
The operator of the equipment — normally the business with control over it. Contractors do the checks; the operator must make sure they happen and keep records.
Need F-gas leak checks in Antrim?
The visit price is agreed before we book. We reply with a guide price or available dates.