Electronic leak detector probe held against brazed copper pipe joints

F-gas leak checks and records in Armagh

F-gas leak checks for premises in Armagh, with records you can show an inspector or insurer.

  • Price confirmed before booking
  • Every system listed and checked
  • Records you can show an inspector

How much do F-gas leak checks cost in Armagh?

Expect £135–£225 per visit, first system ex VAT in Armagh; a typical job — leak checks on 3–6 systems in one visit — usually comes to £255–£795 plus VAT. We confirm the price once we know how many systems you have.

An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.

Our coverage in Armagh

In a town like Armagh, a single wall unit for a shop or a cassette for a surgery makes a real difference in summer.

We work across Armagh's postcode districts, including BT60 and BT61. We also work in nearby Portadown, Dungannon and Craigavon. The legal duty sits with whoever controls the equipment, so tenants and landlords in Armagh should agree who arranges F-gas leak checks.

What is included

  • Refrigerant type, charge and CO2e calculation for each system
  • Leak check by an F-gas certified engineer
  • Direct and indirect checks to the required method
  • Leak repair quote if a leak is found
  • Follow-up check within one month of any repair

F-gas leak checks prices in Armagh

Prices below include our regional adjustment for Northern Ireland (8% below the UK guide).

F-gas leak checks guide prices, Armagh
ItemGuide price (ex VAT)Inc VATBasis
Leak check, first system (includes attendance)£135–£225£162–£270per visit
Each additional system, same visit£60–£115£72–£138per system
F-gas asset register set-upUp to £365Up to £438per site
Automatic leak detection system£730–£2,695£876–£3,234per system

Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.

The visit, step by step

  1. Asset check

    We record each system's refrigerant type and charge and calculate its CO2e.

  2. Set the frequency

    Each system gets the legal interval for its CO2e and any automatic leak detection.

  3. Check

    The engineer checks joints, valves, components and operating data for signs of leakage.

  4. Record

    Results are recorded and kept on your F-gas log for at least five years.

Before you book in Armagh

Northern Ireland

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573 rather than the GB rules. For HFC systems the leak-check thresholds and intervals are the same; it also requires checks on equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants.

Shared buildings

In multi-let buildings, roof space, risers and plant areas are often controlled by a managing agent. We work to their permits and method-statement requirements.

Repairs

If a leak is found it must be repaired without undue delay and re-checked within one month.

Roof and height work

Flat roofs, high walls and atriums need the right access equipment and edge protection. We plan towers, MEWPs or scaffold before the job, not on the day.

Premises we work in around Armagh

Compliance in Northern Ireland: refrigerant work falls under EU F-gas rules that apply in Northern Ireland, and buildings with more than 12 kW of air conditioning in total need a periodic energy inspection (often called TM44).

FAQs for Armagh

How much do F-gas leak checks cost in Armagh?

In Armagh, guide prices are around £135–£225 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT.

Do you also cover Portadown, Dungannon and Craigavon?

Yes. Alongside Armagh, we also cover Portadown, Dungannon and Craigavon. Each has its own page with local guide prices.

Which postcodes do you cover in Armagh?

All of them, including BT60 and BT61. Give us your postcode when you enquire and we will confirm the visit details.

Which systems need F-gas leak checks in Northern Ireland?

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573. For HFC systems the thresholds and intervals match the GB rules — checks from 5 tonnes CO2 equivalent, at least every 12, 6 or 3 months depending on size — and equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants, also needs checks.

How often are leak checks needed?

At least every 12 months from 5 tonnes CO2e, every 6 months from 50 tonnes, and every 3 months from 500 tonnes. Where automatic leak detection is fitted, each interval doubles to 24, 12 and 6 months.

What is CO2 equivalent?

The refrigerant charge in kilograms multiplied by its global warming potential (GWP), divided by 1,000. It puts every refrigerant on the same scale.