0800 088 6248
Electronic leak detector probe held against brazed copper pipe joints

F-gas leak checks and records in Craigavon

F-gas leak checks for premises in Craigavon, with records you can show an inspector or insurer.

  • Price confirmed before booking
  • Every system listed and checked
  • Records you can show an inspector

How much do F-gas leak checks cost in Craigavon?

In Craigavon, guide prices are about £135–£225 per visit, first system, plus VAT. A typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT. The price is confirmed before booking.

An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.

Our coverage in Craigavon

Craigavon has a compact centre of shops, cafés and offices, with business units on its outskirts. Belfast is about 34 km away.

Postcode districts we cover in Craigavon include BT62, BT63, BT64, BT65, BT66 and BT67. Neighbouring towns we cover include Portadown, Banbridge and Armagh. For F-gas leak checks in Craigavon, we start by listing each system, its refrigerant type and charge, so you know exactly what the rules require.

What you get

  • Refrigerant type, charge and CO2e calculation for each system
  • Leak check by an F-gas certified engineer
  • Direct and indirect checks to the required method
  • Labels and records updated
  • Follow-up check within one month of any repair

F-gas leak checks prices in Craigavon

Prices below include our regional adjustment for Northern Ireland (8% below the UK guide).

F-gas leak checks guide prices, Craigavon
ItemGuide price (ex VAT)Inc VATBasis
Leak check, first system (includes attendance)£135–£225£162–£270per visit
Each additional system, same visit£60–£115£72–£138per system
F-gas asset register set-upUp to £365Up to £438per site
Automatic leak detection system£730–£2,695£876–£3,234per system

Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.

How we handle F-gas leak checks in Craigavon

  1. Asset check

    We record each system's refrigerant type and charge and calculate its CO2e.

  2. Set the frequency

    Each system gets the legal interval for its CO2e and any automatic leak detection.

  3. Check

    The engineer checks joints, valves, components and operating data for signs of leakage.

  4. Record

    Results are recorded and kept on your F-gas log for at least five years.

Local points to consider

Northern Ireland

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573 rather than the GB rules. For HFC systems the leak-check thresholds and intervals are the same; it also requires checks on equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants.

Working hours

Most Craigavon businesses prefer noisy work outside trading hours. Early starts, evenings and weekends can be arranged and are priced up front.

Operator duty

The legal duty sits with the operator — the person or business with actual control over the equipment.

Shared buildings

In multi-let buildings, roof space, risers and plant areas are often controlled by a managing agent. We work to their permits and method-statement requirements.

Who we work with in Craigavon

Compliance in Northern Ireland: refrigerant work falls under EU F-gas rules that apply in Northern Ireland, and buildings with more than 12 kW of air conditioning in total need a periodic energy inspection (often called TM44).

Common questions from businesses in Craigavon

How much do F-gas leak checks cost in Craigavon?

In Craigavon, guide prices are around £135–£225 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT.

Do you also cover Portadown, Banbridge and Armagh?

Yes. Alongside Craigavon, we also cover Portadown, Banbridge and Armagh. Each has its own page with local guide prices.

Which postcodes do you cover in Craigavon?

All of them, including BT62, BT63, BT64 and BT65. Give us your postcode when you enquire and we will confirm the visit details.

Which systems need F-gas leak checks in Northern Ireland?

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573. For HFC systems the thresholds and intervals match the GB rules — checks from 5 tonnes CO2 equivalent, at least every 12, 6 or 3 months depending on size — and equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants, also needs checks.

How long must records be kept?

For at least five years, covering refrigerant type and quantity, additions and recoveries, leak-check dates and results, and who carried out the work.

Who is responsible for F-gas compliance?

The operator of the equipment — normally the business with control over it. Contractors do the checks; the operator must make sure they happen and keep records.

Get a guide price for Craigavon

The visit price is agreed before we book. We reply with a guide price or available dates.

CallGet a quote