Electronic leak detector probe held against brazed copper pipe joints

F-gas leak checks and records in Canary Wharf

Stay compliant in Canary Wharf: F-gas leak checks arranged, recorded and followed up.

  • Price confirmed before booking
  • Every system listed and checked
  • Records you can show an inspector

How much do F-gas leak checks cost in Canary Wharf?

In Canary Wharf, guide prices are about £185–£315 per visit, first system, plus VAT. A typical job (leak checks on 3–6 systems in one visit) is £345–£1,095 plus VAT. You get the price before the visit is booked.

An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.

Canary Wharf and surrounding areas

Canary Wharf sits within London's dense commercial fabric: shopfronts, offices above, studios and venues, where outdoor unit positions and access need careful planning.

We work across Canary Wharf's postcode districts, including E14 and SE16. Nearby, we also cover Bow (about 2 km), Canning Town (about 3 km) and Greenwich (about 3 km). The legal duty sits with whoever controls the equipment, so tenants and landlords in Canary Wharf should agree who arranges F-gas leak checks.

Included as standard

  • Refrigerant type, charge and CO2e calculation for each system
  • Leak check by an F-gas certified engineer
  • Labels and records updated
  • Leak repair quote if a leak is found
  • Follow-up check within one month of any repair

Guide prices in Canary Wharf

Prices below include our regional adjustment for London (28% above the UK guide).

F-gas leak checks guide prices, Canary Wharf
ItemGuide price (ex VAT)Inc VATBasis
Leak check, first system (includes attendance)£185–£315£222–£378per visit
Each additional system, same visit£85–£160£102–£192per system
F-gas asset register set-upUp to £505Up to £606per site
Automatic leak detection system£995–£3,795£1,194–£4,554per system

Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.

What happens on a visit in Canary Wharf

  1. Asset check

    We record each system's refrigerant type and charge and calculate its CO2e.

  2. Set the frequency

    Each system gets the legal interval for its CO2e and any automatic leak detection.

  3. Check

    The engineer checks joints, valves, components and operating data for signs of leakage.

  4. Record

    Results are recorded and kept on your F-gas log for at least five years.

Things to check in Canary Wharf

Repairs

If a leak is found it must be repaired without undue delay and re-checked within one month.

Access and parking

Town-centre jobs in Canary Wharf often come down to access — loading restrictions, parking for the van and getting equipment onto a roof. We check this at survey and plan deliveries around it.

Operator duty

The legal duty sits with the operator — the person or business with actual control over the equipment.

Leased premises

If your Canary Wharf premises are leased, the landlord's written consent is usually needed for external units, wall penetrations and roof access. We provide drawings and data sheets for the request.

Who we work with in Canary Wharf

In England, systems holding 5 tonnes CO2 equivalent of refrigerant or more fall under GB F-gas rules, with regular leak checks and records; buildings with more than 12 kW of air conditioning in total also need a periodic energy inspection.

FAQs for Canary Wharf

How much do F-gas leak checks cost in Canary Wharf?

In Canary Wharf, guide prices are around £185–£315 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £345–£1,095 plus VAT.

Do you also cover Bow, Canning Town and Greenwich?

Yes. Alongside Canary Wharf, we also cover Bow, Canning Town and Greenwich. Each has its own page with local guide prices.

Which postcodes do you cover in Canary Wharf?

All of them, including E14 and SE16. Give us your postcode when you enquire and we will confirm the visit details.

How often are leak checks needed?

At least every 12 months from 5 tonnes CO2e, every 6 months from 50 tonnes, and every 3 months from 500 tonnes. Where automatic leak detection is fitted, each interval doubles to 24, 12 and 6 months.

How long must records be kept?

For at least five years, covering refrigerant type and quantity, additions and recoveries, leak-check dates and results, and who carried out the work.

Get a guide price for Canary Wharf

The visit price is agreed before we book. We reply with a guide price or available dates.

CallGet a quote