F-gas leak checks and records in County Tyrone

Stay compliant in County Tyrone: F-gas leak checks arranged, recorded and followed up.

  • Price confirmed before booking
  • Every system listed and checked
  • Records you can show an inspector

How much do F-gas leak checks cost in County Tyrone?

In County Tyrone, guide prices are about £135–£225 per visit, first system, plus VAT. A typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT. The price is confirmed before booking.

An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.

County Tyrone and surrounding areas

We cover all of County Tyrone, including Omagh, Strabane, Dungannon and Cookstown. We quote for premises right across County Tyrone, including rural and edge-of-town sites.

Postcode districts we cover include BT68, BT69, BT71, BT75, BT77, BT78, BT80 and BT82. The legal duty sits with whoever controls the equipment, so tenants and landlords in County Tyrone should agree who arranges F-gas leak checks.

What the job covers

  • Refrigerant type, charge and CO2e calculation for each system
  • Direct and indirect checks to the required method
  • Labels and records updated
  • Leak repair quote if a leak is found
  • Follow-up check within one month of any repair

F-gas leak checks prices in County Tyrone

Prices below include our regional adjustment for Northern Ireland (8% below the UK guide).

F-gas leak checks guide prices, County Tyrone
ItemGuide price (ex VAT)Inc VATBasis
Leak check, first system (includes attendance)£135–£225£162–£270per visit
Each additional system, same visit£60–£115£72–£138per system
F-gas asset register set-upUp to £365Up to £438per site
Automatic leak detection system£730–£2,695£876–£3,234per system

Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.

What happens on a visit in County Tyrone

  1. Asset check

    We record each system's refrigerant type and charge and calculate its CO2e.

  2. Set the frequency

    Each system gets the legal interval for its CO2e and any automatic leak detection.

  3. Check

    The engineer checks joints, valves, components and operating data for signs of leakage.

  4. Record

    Results are recorded and kept on your F-gas log for at least five years.

Points to plan for in County Tyrone

Northern Ireland

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573 rather than the GB rules. For HFC systems the leak-check thresholds and intervals are the same; it also requires checks on equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants.

Working hours

Most County Tyrone businesses prefer noisy work outside trading hours. Early starts, evenings and weekends can be arranged and are priced up front.

Operator duty

The legal duty sits with the operator — the person or business with actual control over the equipment.

Access and parking

Town-centre jobs in County Tyrone often come down to access — loading restrictions, parking for the van and getting equipment onto a roof. We check this at survey and plan deliveries around it.

Premises we work in around County Tyrone

Two rules matter for most businesses in Northern Ireland: EU F-gas rules that apply in Northern Ireland (leak checks from 5 tonnes CO2e) and the periodic energy inspection for more than 12 kW of air conditioning.

Your questions answered

How much do F-gas leak checks cost in County Tyrone?

In County Tyrone, guide prices are around £135–£225 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT.

Do you also cover County Londonderry, County Fermanagh and County Armagh?

Yes. Alongside County Tyrone, we also cover County Londonderry, County Fermanagh and County Armagh. Each has its own page with local guide prices.

Which systems need F-gas leak checks in Northern Ireland?

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573. For HFC systems the thresholds and intervals match the GB rules — checks from 5 tonnes CO2 equivalent, at least every 12, 6 or 3 months depending on size — and equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants, also needs checks.

How often are leak checks needed?

At least every 12 months from 5 tonnes CO2e, every 6 months from 50 tonnes, and every 3 months from 500 tonnes. Where automatic leak detection is fitted, each interval doubles to 24, 12 and 6 months.

How long must records be kept?

For at least five years, covering refrigerant type and quantity, additions and recoveries, leak-check dates and results, and who carried out the work.

Get a guide price for County Tyrone

The visit price is agreed before we book. We reply with a guide price or available dates.

CallGet a quote