0800 088 6248
Electronic leak detector probe held against brazed copper pipe joints

F-gas leak checks and records in Cookstown

F-gas leak checks for premises in Cookstown, with records you can show an inspector or insurer.

  • Price confirmed before booking
  • Every system listed and checked
  • Records you can show an inspector

How much do F-gas leak checks cost in Cookstown?

Expect £135–£225 per visit, first system ex VAT in Cookstown; a typical job — leak checks on 3–6 systems in one visit — usually comes to £255–£795 plus VAT. You get the price before the visit is booked.

An F-gas leak check is a legally required inspection of air conditioning and refrigeration equipment containing fluorinated gases at or above 5 tonnes CO2 equivalent.

Working in Cookstown

Most commercial premises in and around Cookstown are shops, offices, salons, pubs and small industrial units.

We work across Cookstown's postcode districts, including BT80. Nearby, we also cover Magherafelt (about 15 km), Dungannon (about 16 km) and Portadown (about 31 km). The legal duty sits with whoever controls the equipment, so tenants and landlords in Cookstown should agree who arranges F-gas leak checks.

What we do

  • Refrigerant type, charge and CO2e calculation for each system
  • Leak check by an F-gas certified engineer
  • Direct and indirect checks to the required method
  • Leak repair quote if a leak is found
  • Follow-up check within one month of any repair

F-gas leak checks prices in Cookstown

These guide prices are adjusted for Northern Ireland, where labour and access costs run about 8% below the UK guide.

F-gas leak checks guide prices, Cookstown
ItemGuide price (ex VAT)Inc VATBasis
Leak check, first system (includes attendance)£135–£225£162–£270per visit
Each additional system, same visit£60–£115£72–£138per system
F-gas asset register set-upUp to £365Up to £438per site
Automatic leak detection system£730–£2,695£876–£3,234per system

Ex VAT. Leak checks are often combined with a service visit at no extra attendance charge.

How a visit in Cookstown works

  1. Asset check

    We record each system's refrigerant type and charge and calculate its CO2e.

  2. Set the frequency

    Each system gets the legal interval for its CO2e and any automatic leak detection.

  3. Check

    The engineer checks joints, valves, components and operating data for signs of leakage.

  4. Record

    Results are recorded and kept on your F-gas log for at least five years.

Local points to consider

Northern Ireland

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573 rather than the GB rules. For HFC systems the leak-check thresholds and intervals are the same; it also requires checks on equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants.

Roof and height work

Flat roofs, high walls and atriums need the right access equipment and edge protection. We plan towers, MEWPs or scaffold before the job, not on the day.

Operator duty

The legal duty sits with the operator — the person or business with actual control over the equipment.

Conservation areas

Historic streets and listed buildings in and around Cookstown are more likely to need planning permission for outdoor units on visible elevations. We check with the council's planning service before work is booked.

Typical premises in Cookstown

Two rules matter for most businesses in Northern Ireland: EU F-gas rules that apply in Northern Ireland (leak checks from 5 tonnes CO2e) and the periodic energy inspection for more than 12 kW of air conditioning.

Common questions from businesses in Cookstown

How much do F-gas leak checks cost in Cookstown?

In Cookstown, guide prices are around £135–£225 per visit, first system, plus VAT; a typical job (leak checks on 3–6 systems in one visit) is £255–£795 plus VAT.

Do you also cover Magherafelt, Dungannon and Portadown?

Yes. Alongside Cookstown, we also cover Magherafelt, Dungannon and Portadown. Each has its own page with local guide prices.

Which postcodes do you cover in Cookstown?

All of them, including BT80. Give us your postcode when you enquire and we will confirm the visit details.

Which systems need F-gas leak checks in Northern Ireland?

Northern Ireland follows the EU F-gas Regulation (EU) 2024/573. For HFC systems the thresholds and intervals match the GB rules — checks from 5 tonnes CO2 equivalent, at least every 12, 6 or 3 months depending on size — and equipment holding 1 kg or more of certain other fluorinated gases, such as HFO refrigerants, also needs checks.

How long must records be kept?

For at least five years, covering refrigerant type and quantity, additions and recoveries, leak-check dates and results, and who carried out the work.

How often are leak checks needed?

At least every 12 months from 5 tonnes CO2e, every 6 months from 50 tonnes, and every 3 months from 500 tonnes. Where automatic leak detection is fitted, each interval doubles to 24, 12 and 6 months.

Get a guide price for Cookstown

The visit price is agreed before we book. We reply with a guide price or available dates.

CallGet a quote